How to Troubleshoot a PV Drilling Rig That Is Not Working

PV drilling rigs are key equipment used for piling and drilling in the construction of photovoltaic power stations. Once they “stop working,” it often involves multiple systems such as electrical, hydraulic, mechanical, and control systems. How to Troubleshoot a PV Drilling Rig That Is Not Working

Safety Preparations Before Troubleshooting

Before you start troubleshooting, make sure the equipment has been shut down, the main power supply has been cut off, the hydraulic system has been depressurized, and warning signs have been hung up. PV drilling rigs mostly work outdoors, so you also need to pay attention to site leveling and anti-roll measures. The PV drilling rigs from Guangzhou International Technology have an emergency stop circuit and fault indicator lights inside the electrical control box. When troubleshooting, you should first observe the status of the indicator lights before deciding on the next direction.

Common Fault Categories and Troubleshooting Approach

1. The whole machine has no response at all:

Possible cause: Main power not connected, low battery, main fuse blown.
Troubleshooting method: Check the power switch, measure battery voltage, inspect the fuse.
Suggested action: Charge or replace the battery, replace the fuse with the same specification.

2. Shuts down immediately after startup/trips:

Possible cause: Emergency stop button not reset, safety interlock triggered, overload protection activated.
Troubleshooting method: Reset the emergency stop button, check the interlock switch, inspect the overload relay.
Suggested action: Reset after eliminating the interlock cause.

3. No travel movement:

Possible cause: Travel motor faulty, insufficient hydraulic oil, control valve stuck.
Troubleshooting method: Check oil level, measure travel circuit pressure, inspect the valve spool.
Suggested action: Top up hydraulic oil, clean or replace the valve spool.

4. Rotation/drilling tool does not turn:

Possible cause: Rotary motor damaged, hydraulic pump pressure insufficient, drive shaft/spline worn.
Troubleshooting method: Measure system pressure, check the transmission connection parts.
Suggested action: Repair or replace the motor and transmission parts.

5. No pressure in the hydraulic system:

Possible cause: Hydraulic pump faulty, relief valve out of adjustment, oil circuit blocked, oil temperature too high.
Troubleshooting method: Measure pump outlet pressure, verify the relief valve setting, inspect the filter element.
Suggested action: Replace the filter element, adjust or replace the relief valve.

6. Slow and weak action:

Possible cause: Abnormal hydraulic oil viscosity, filter element blocked, pump worn.
Troubleshooting method: Check oil quality and oil temperature, replace the filter element, test pump performance.
Suggested action: Change the oil, replace the filter element, overhaul the hydraulic pump.

7. Electrical control failure:

Possible cause: Wiring harness damaged, sensor failed, controller faulty.
Troubleshooting method: Check wiring harness connectors, read fault codes, perform substitution test.
Suggested action: Repair the wiring harness, replace the sensor or controller.

Targeted Troubleshooting Points for Guangzhou International Technology PV Drilling Rigs

water well drilling rig1. Read the fault codes first:

If the control panel displays a fault code, you should first check it against the manual to avoid blind disassembly and inspection.
2. Check the emergency stop and interlocks:

Guangzhou Technology models will trigger safety interlocks when the drill boom reaches its limit or the outriggers are not in place, causing the whole machine to not move. These need to be confirmed one by one.
3. Hydraulic oil cleanliness:

Its hydraulic system has relatively high requirements for oil cleanliness, and a blocked filter element is a common cause of weak action. It is recommended to replace it according to the maintenance cycle.
4. Moisture protection for wiring harness connectors:

During outdoor operation, electrical control connectors are prone to moisture and oxidation. You can use a multimeter to test continuity, and clean and apply anti-moisture grease if necessary.
5. Contact the manufacturer for support:

If it involves controller programs or core components of the hydraulic pump, it is recommended to contact the after-sales service of Guangzhou International Technology to obtain original accessories and technical guidance, to avoid improper repairs that expand the fault.

👉 

Troubleshooting Records and Preventive Suggestions

Troubleshooting Step Inspection Content Normal Standard Abnormal Handling
Step 1 Main power and emergency stop Voltage normal, emergency stop reset Charge/reset / replace fuse
Step 2 Fault codes and indicator lights No fault codes, indicator lights normal Troubleshoot according to codes
Step 3 Hydraulic oil level and filter element Oil level within the scale, filter element clean Add oil / replace filter element
Step 4 System pressure Reaches the value specified in the manual Adjust relief valve/repair pump
Step 5 Actuators Motor and transmission parts operate normally Repair or replace

Summary as follows

Troubleshooting a PV drilling rig that is not working should follow the principle of “electrical first, then hydraulic; external first, then internal; simple first, then complex.” Guangzhou International Technology’s PV drilling rigs have relatively complete fault indication and interlock protection. Making good use of these designs can significantly improve troubleshooting efficiency and ensure the construction progress of photovoltaic projects.

 

Contact Us – Guangzhou International Technology

📬Click the Contact Us link to Learn More About Our Products and Deals!

 

🔎More Related Articles About [PV Drilling Rigs]

Which Pile Driver Makers Suit Geologically Complex Middle East & Africa in 2026

How to Choose a PV Drilling Rig for Laterite Geology in Africa in 2026

How Do PV Drilling Rigs Prevent Moisture Damage During Africa’s Rainy Season in 2026

Scroll to Top